Supply voltage, V: |
K60 controllers, UP, TSE (direct current): 12.0... 30.0; CCP, WKS (50 Hz alternating current): 220 |
Operating temperature range, °С: |
K60 controllers: - 40... + 50; CCP, WKS, UP: +5...35; TSE: -50...+60 |
Control of access points, pcs: | 60 |
Control of electronic units of digital detectors, pcs: | 120 |
To each RS-485 cable the following devices can be connected, pcs: |
any combination of controllers, PP and LPU - 30; electronic units of digital detectors - 30. |
A hardware-software complex, intended to build an integrated security system for small-size and medium-size facilities with the function of security alarm system, data acquisition and processing system, access control system, CCTV.
Components:
1. High reliability based on data and equipment backup:
3. A wide range of used digital detectors produced by NIKIRET, including:
4. Digital detectors provide:
5. Individual rigths separation of each operator to grant access to information and controls.
6. Remote control and detector adjustment using mobile devices based on OC Android system or PKU-R.
7. Connection using the adapter БАЖК.464424.004 with interface of "dry contact" type to RS-485 line.
8. Registration and message archiving of all events related to the state change of actuators and communication channels, actions of subscribers and operators including ARM, CCP.
Article | БАЖК.425621.030 |
Supply voltage, V |
K60 controllers, UP, TSE (direct current): 12.0... 30.0; CCP, WKS (50 Hz alternating current): 220 |
Operating temperature range, °С |
K60 controllers: - 40... + 50; CCP, WKS, UP: +5...35; TSE: -50...+60 |
Control of access points, pcs | 60 |
Control of electronic units of digital detectors, pcs | 120 |
To each RS-485 cable the following devices can be connected, pcs |
any combination of controllers, PP and LPU - 30; electronic units of digital detectors - 30. |
Maximum number of detectors connected to controllers K60, pcs | 240 |
Maximum cable length (with repeaters used), km | 5 |
Number of RS-485 cables | 4 |
Message archive capacity | 20 000 |
Maximum distance from controller to detector, m | 250 |