Vibration seismic detection of intruder overpassing the fence by climbing over, destroying or digging under moving on the ground surface.
Supply voltage, V: 12.0...30.0
Detection zone length, m: analog cable VSE, m - up to 500 (2x250);
analog cable VSE anti-digging one, m - up to 500 (2x250);
analog single-point VSE, m - up to 40 zones (2x20);
digital cable VSE, m - up to 2000 (2x1000);
digital SSE - up to 500 (2x250);
combined (analog VSE + digital SSE), m - up to 500 (2x250)
Power consumption, Watt: in standby mode (when RS-485 interface is off), maximum - 0.25;
in standby mode (when RS-485 interface is on), maximum - 0.5;
in setting mode, maximum - 1.0
Heating power supply voltage, V: 20.0... 30.0
Power consumed by digital link of VSE/SSE, Watt: 0.09/0.09
Article:
БАЖК.425118.004
Produced by the enterprise of State Atomic Energy Corporation Rosatom
  • Description
  • Performance Specifications
  • Purpose

    Vibration seismic detection of intruder overpassing the fence by climbing over, destroying or digging under moving on the ground surface.

    The detector is intended to build lengthy protected boundaries, perimeters of facilities, small-size facilities, to monitor entry points and road approaches to the outer perimeter of protected facility.

    The principle of operation is based on transformation of mechanical oscillations of the fence and/or ground vibrations into electric signals with the postprocessing of signals and transfer of an alarm to DADS.

    During the analog vibration mode of operation, the detector generates an alarm signal according to the results received from the sensing element - an analog cable or single-point vibration sensing element (VSE). During the digital mode of operation, the detector generates an alarm signal according to the results received from the sensing element - a digital seismic sensing element (SSE) or a digital vibration sensitng VSE. During the combined mode of operation, the detector generates an alarm signal according to the results of the combined signal processing received from the VSE and the SSE of the site.

    Components:
    • Electronic unit 1 pcs.
    • Sensing element *
    • Mounting kit to fix VSE on different types of fences*:
      • - MK-SE БЖАК.305651.013
        - MK-VB БАЖК.468921.001
        - MK-U БАЖК.468921.007
        - MK-P БАЖК.468921.008
    • Inserts to build non-sensitive zones of VSE and SSE*:
      • - VSE insert БАЖК.685691.044 (10, 25, 50, 100 m)
        - SSE insert БАЖК.685691.043 (20, 40, 60, 80, 100 m)
    • Repair part kits*:
      • - connectors БАЖК.425919.032
        - actuators БАЖК.425919.033
    * - Type, quantity and length are determined under a separate order.

    Distinctive features:
    • Passive principle of operation that does not generate electromagnetic oscillations in environment. 
    • Universality - used as vibration, seismic or combined detector, include digital or analog sensing elements.
    • to operate with all access control systems jointed with peripheral external devices via RS-485 interface or relay "dry contacts".
    • Keyboard lock is provided to except the unathorized changes in operation time and specified algorithm. 
  • Article БАЖК.425118.004
    Supply voltage, V 12.0...30.0
    Detection zone length, m analog cable VSE, m - up to 500 (2x250);
    analog cable VSE anti-digging one, m - up to 500 (2x250);
    analog single-point VSE, m - up to 40 zones (2x20);
    digital cable VSE, m - up to 2000 (2x1000);
    digital SSE - up to 500 (2x250);
    combined (analog VSE + digital SSE), m - up to 500 (2x250)
    Power consumption, Watt in standby mode (when RS-485 interface is off), maximum - 0.25;
    in standby mode (when RS-485 interface is on), maximum - 0.5;
    in setting mode, maximum - 1.0
    Heating power supply voltage, V 20.0... 30.0
    Power consumed by digital link of VSE/SSE, Watt 0.09/0.09
    Power consumed via heating circuit (at 24 V), Watt, maximum 5.0
    Operating temperature range of EU, °С for standard modificaton -50...+50;
    for artic modification -60...+60
    Operating temperature range of digital SE, °С analog VSE -60...+60;
    digital VSE and SSE -40...+50
  • 
    Защита от автоматических сообщений
    Введите слово на картинке*
    CAPTCHA
Быстрый заказ товара

Оставьте ваши контакты, и наш менеджер свяжется с Вами в ближайшее время.

  • Защита от автоматических сообщений
    Введите слово на картинке*
    CAPTCHA
Ask a question

Use the contact form to get in touch with us, our specialist will attend to your request shortly.


Order a call back

Use the contact form to get in touch with us, our specialist will attend to your request shortly.